Protective Clothing
Radiant Heat Cover
Rated to 1000°C
Aluminized radiant heat cover for up to 1000°C radiant heat. Double-layer 50cm cape, worn over a safety helmet, in Basic (PT01002) and Advanced (PT02002) grades.
Aluminized hood
Radiant heat cover for 1000°C radiant heat
A double-layer aluminized hood that protects the head, neck and shoulders.
The aluminized shell turns radiant heat away. A flame-retardant cotton lining sits underneath.
It fits over a snap-on safety helmet, so the head stays protected from knocks too.

1000°C
Radiant heat protection
50cm
Double-layer cape
2
Grades: Basic and Advanced
1 size
Fits over a safety helmet
Specifications
Radiant heat cover specifications
The cover is sold on its own or as part of a full heat protective suit.
| Model number | PT01002 (Basic), PT02002 (Advanced) |
|---|---|
| Radiant heat | Up to 1000°C |
| Outer shell | Basic: composite aluminium foil on modified fibreglass cloth. Advanced: aluminized carbon fibre blend fireproof cloth |
| Lining | Flame-retardant cotton |
| Cape | 50cm, double layer |
| Fitting | Worn with a snap-on safety helmet |
| Protection | Radiant heat, molten metal splash, flame |
| Brand | PD |
| Origin | Guangdong, China |

Two grades
Basic or Advanced radiant heat cover, same 1000°C rating
01
Basic — PT01002
Composite aluminium foil on modified fibreglass cloth, with a flame-retardant cotton lining. Full radiant heat protection at the lower price.
02
Advanced — PT02002
Aluminized carbon fibre blend shell over the same lining. It takes abrasion and folding better, so it lasts longer on rough jobs.
03
Match the suit
Pick the same grade as your heat protective clothing so the whole set wears evenly.
Design
Built to cover the head, neck and shoulders
The cape drops 50cm over the shoulders in two layers. Heat and sparks cannot reach the collar gap.
The lining is soft and breathable, and it wicks sweat on long shifts.
The front screen gives a clear view of the work.

Test data
Tested fabric values
The cover uses the same shell and lining fabrics as our heat protective clothing.
| Test | Aluminized outer shell | Flame-retardant lining |
|---|---|---|
| Flame retardance | Damaged length ≤100mm, afterflame ≤2s, no melting or dripping | Damaged length ≤100mm, afterflame ≤2s, no melting or dripping |
| Thermal stability | 260°C, dimensional change ≤10% warp and weft | 180°C, dimensional change ≤10% warp and weft |
| Breaking strength | ≥650N warp and weft | ≥500N warp and weft |
| Tear strength | ≥100N warp and weft | ≥500N warp and weft |
| Peel strength | ≥9N warp and weft | ≥9N warp and weft |
| Hydrostatic pressure | ≥17kPa | ≥17kPa |
Test items follow XF 634-2015, the Chinese standard for firefighter heat-insulating clothing.

Application
Where the radiant heat cover is worn
Foundries, steel and aluminium smelting, and glass hot work.
Boiler and kiln jobs, and hot repairs close to a furnace.
Wear it with the suit, gloves and foot covers for full protection.
FAQ
Radiant heat cover questions
Do I need a helmet with it?
Yes. The cover is designed to fit over a snap-on safety helmet.
Basic or Advanced?
Advanced suits daily shifts, sharp scrap and heavy handling.
Basic covers standard furnace and oven work.
Is it for walking into flame?
No. It protects against radiant heat and splash near the heat source.
Fire entry needs a different build.
Which standard are the fabrics tested to?
The test items follow XF 634-2015 for firefighter heat-insulating clothing.
Can I buy the cover without the suit?
Yes. Every piece of the set is sold on its own.
PD FELT · Foshan, China
Need a custom Radiant Heat Cover?
Tell us the machine, the position on the line and the temperature. We make the felt to your drawing.